CLEANLINE T-10K33LV2 10kVA/10kW เครื่องสำรองไฟ UPS True On-Line Double Conversion T-SERIES

Manufacturer: CLEANLINE
CLEANLINE T-10K 33 LV2 10000VA/10000W True on-line double conversion design UPS T-SERIES. Pure Sine Wave Output Intelligent Graphic LCD Display Long Run With Battery Pack. Downloadable UPS Monitoring Software
SKU: เครื่อง/set
Call for pricing
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options

CLEANLINE T-10K 33 LV2 10000VA/10000W True on-line double conversion design UPS T-SERIES

Features :

  • True on-line double conversion design UPS
  • Fully Digitized Microprocessor Controlled
  • Wide input voltage range 110-300Vac
  • Unity output power factor
  • 50/60 Hz frequency converter mode
  • MIMIC LCD for real-tme UPS status display
  • Auto self-testing system while turning on UPS
  • Eco mode operation for energy saving
  • Emergency power off (EPO) function
  • Programmable power management outlets
  • Selectable output voltage via LCD panel
  • Cold start function
  • Smart battery charger design to optimize battery performance
  • Battery charger with temperature compensation technology
  • Short circuit protection
  • Lightning and surge protection
  • Built-in USB and RS-232 communications port for management software
  • Generator compatible
  • Optional external maintenance bypass switch
  • Optional compatible with SNMP protocol
  • Dimension, D x W x H (mm) 630 x 250 x 826
  • Net Weiight (kgs) 28
  • Standards and Approvals : ISO 9001, ISO 14001 & TIS. 1291 Part 1-2553, TIS. 1291 Part 2-2553, TIS. 1291 Part 3-2555

KEY Features:
•True double conversion with DSP technologyDouble conversion between input/output, battery andbypass are totally isolated power line noise, spike and transients, keeping power faillure awayfrom your critical loads.
•Output power factor 0.9 For critical applications, this 3-phase online UPS with output power factor 0.9 ensures higher efficiency and advanced performance.
•Active power factor correction in all phases Power factor correction is active in all phases and it can improve the efficiency of input.
•50Hz/60Hz frequency converter mode Lock output frequency at 50Hz or 60Hz to suit power sensitive equipments.
•ECO mode operation for energy saving ECO mode improves the efficiency up to 98% to cut energy usage & cost. In this mode, loads are supplied by the mains directly. While mains faillure, the UPS will constantly supply the power to the connected device without any interruption.
•Emergency power off function (EPO) In case of any emergency and fire, the EPO control mechanism can instantly shut down the system.
•Optional parallel operation with common battery The system can be operated in parallel, increasing the capacity and performance. Besides, this parallel UPS system can share common battery packs which might greatly reduce the expense and reach the same performance up to 6 units.
•Smart battery charger design to optimize battery performance This UPS is equipped. with 3-stage charger for optimize battery performance. This feature extends the useful service life of battery and optimizes battery recharge time.
•LED, LCD 5” touch for T-10K33LV2 Plus - T-80K33LV2 Plus models

CLEANLINE T-SERIES 
MODEL T-10K33LV2 T-15K33LV2 T-20K33LV2 T-30K33LV2 T-40K33LV2 T-60K33LV2 T-80K33LV2
PHASE 1-phase in/1-phase out, 3-phase in/1-phase out or 3 -phase in/3-phase out 3-phase in/3-phase out
TOTAL CAPACITY 10kVA/10kW 15kVA/15kW 20kVA/20kW 30kVA/30kW 40kVA/40kW 60kVA/60kW 80kVA/80kW
TOPOLOGY True On-line Double Conversion
INPUT
Nominal Voltage 1 x 220/230/240 VAC (1-Ph+N) or 3 x 380/400/415 VAC (3-Ph+N) 3 x 380/400/415 VAC (3-Ph+N)
Voltage Range 161-276 VAC (1-phase) @ 100% load
280-480 VAC (3-phase) @ 100% load
280-480 VAC (3-phase) @ 100% load
Frequency Range 40-70Hz
Power Factor ≥0.99 @ 100% load
Harmonic Distortion (THDi) < 3% at full linear load
OUTPUT
Output Voltage 1 x 220/230/240 VAC (1-Ph+N) or 3 x 380/400/415 VAC (3-Ph+N) 3 x 380/400/415 VAC (3-Ph+N)
Voltage Regulation (Steady state) ≤±1% Typical (balanced load); ≤±2% Typical (unbalanced load)
Voltage Recvoery Time ±1% at 10 ms
Frequency Range (Synchronized Range) 50Hz or 60Hz ±1%, ±2%, ±4%, ±8% (adjustable)
Frequency Range (Batt. Mode) 50Hz or 60 Hz ±0.1Hz
Current Crest Ratio 3:1 (max.)
Harmonic Distortion ≤1% THD (Linear Load); ≤3% THD (Non-linear load)
Transfer AC Mode to Batt. Mode Zero
Time Inverter to Bypass Zero
Waveform (Batt. Mode) Pure Sine wave
Overload AC Mode >100-110% for 60 min >110-125% for 10 min >125-150% for 1 min
Battery Mode >100-110% for 60 min >110-125% for 10 min >125-150% for 1 min
Parallel Capacity up to 6 units in parallel
EFFICIENCY
AC Mode 96.0%
ECO Mode 99.0%
Battery Mode 96.0%
BATTERY
Typical Recharge Time 9 hours recover to 90% capacity
Internal Battery 20pcs 32pcs 64pcs -
Charging Current (max.) 12A 16A 24A 32A
INDICATORS
LCD Display 5" monochrome LCD" Touch Type color LCD
UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault Conditions
ALARM
Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continously sounding
PHYSICAL
Dimension, D x W x H (mm) 630 x 250 x 826 815 x 300 x 1000 790 x 360 x 1010
Net Weiight (kgs) 124 139 225 250 108 113
ENVIRONMENT
Operation Temperture 0-40° C
Operation Humidity <95% and non-condersing
Noise Levell Less than 60dB @ 1 Meter Less than 63dB @ 1 Meter Less than 65dB @ 1 Meter
MANAGEMENT
Smart RS-232 / USB Supports Windows 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux and MAC
Optional SNMP Power management from SNMP manager and web browse
STANDARDS
Safety IEC/EN 62040-1
EMC IEC/EN 62040-2 IEC/EN 62040-3
Accessories and Optional Isolation Transformers, SNMP-Adapter