CLEANLINE T-SERIES |
MODEL |
T-10K33LV2 |
T-15K33LV2 |
T-20K33LV2 |
T-30K33LV2 |
T-40K33LV2 |
T-60K33LV2 |
T-80K33LV2 |
PHASE |
1-phase in/1-phase out, 3-phase in/1-phase out or 3 -phase in/3-phase out |
3-phase in/3-phase out |
TOTAL CAPACITY |
10kVA/10kW |
15kVA/15kW |
20kVA/20kW |
30kVA/30kW |
40kVA/40kW |
60kVA/60kW |
80kVA/80kW |
TOPOLOGY |
True On-line Double Conversion |
INPUT |
Nominal Voltage |
1 x 220/230/240 VAC (1-Ph+N) or 3 x 380/400/415 VAC (3-Ph+N) |
3 x 380/400/415 VAC (3-Ph+N) |
Voltage Range |
161-276 VAC (1-phase) @ 100% load 280-480 VAC (3-phase) @ 100% load |
280-480 VAC (3-phase) @ 100% load |
Frequency Range |
40-70Hz |
Power Factor |
≥0.99 @ 100% load |
Harmonic Distortion (THDi) |
< 3% at full linear load |
OUTPUT |
Output Voltage |
1 x 220/230/240 VAC (1-Ph+N) or 3 x 380/400/415 VAC (3-Ph+N) |
3 x 380/400/415 VAC (3-Ph+N) |
Voltage Regulation (Steady state) |
≤±1% Typical (balanced load); ≤±2% Typical (unbalanced load) |
Voltage Recvoery Time |
±1% at 10 ms |
Frequency Range (Synchronized Range) |
50Hz or 60Hz ±1%, ±2%, ±4%, ±8% (adjustable) |
Frequency Range (Batt. Mode) |
50Hz or 60 Hz ±0.1Hz |
Current Crest Ratio |
3:1 (max.) |
Harmonic Distortion |
≤1% THD (Linear Load); ≤3% THD (Non-linear load) |
Transfer |
AC Mode to Batt. Mode |
Zero |
Time |
Inverter to Bypass |
Zero |
Waveform (Batt. Mode) |
Pure Sine wave |
Overload |
AC Mode |
>100-110% for 60 min >110-125% for 10 min >125-150% for 1 min |
Battery Mode |
>100-110% for 60 min >110-125% for 10 min >125-150% for 1 min |
Parallel Capacity |
up to 6 units in parallel |
EFFICIENCY |
AC Mode |
96.0% |
ECO Mode |
99.0% |
Battery Mode |
96.0% |
BATTERY |
Typical Recharge Time |
9 hours recover to 90% capacity |
Internal Battery |
20pcs |
32pcs |
64pcs |
- |
Charging Current (max.) |
12A |
16A |
24A |
32A |
INDICATORS |
LCD Display |
5" monochrome LCD" Touch Type color LCD UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault Conditions |
ALARM |
Battery Mode |
Sounding every 4 seconds |
Low Battery |
Sounding every second |
Overload |
Sounding twice every second |
Fault |
Continously sounding |
PHYSICAL |
Dimension, D x W x H (mm) |
630 x 250 x 826 |
815 x 300 x 1000 |
790 x 360 x 1010 |
Net Weiight (kgs) |
124 |
139 |
225 |
250 |
108 |
113 |
ENVIRONMENT |
Operation Temperture |
0-40° C |
Operation Humidity |
<95% and non-condersing |
Noise Levell |
Less than 60dB @ 1 Meter |
Less than 63dB @ 1 Meter |
Less than 65dB @ 1 Meter |
MANAGEMENT |
Smart RS-232 / USB |
Supports Windows 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux and MAC |
Optional SNMP |
Power management from SNMP manager and web browse |
STANDARDS |
Safety |
IEC/EN 62040-1 |
EMC |
IEC/EN 62040-2 IEC/EN 62040-3 |
Accessories and Optional |
Isolation Transformers, SNMP-Adapter |